{"product_id":"nsk-nlz-e-electric-micromotor-system-with-endodontic-function","title":"NSK NLZ-E Electric Micromotor System with Endodontic Function","description":"\u003cp\u003eNow in a more compact size, with higher safety and flexibility for different installation styles, NSK’s all new “NLZ” can help any user of air driven handpieces convert to electric and enjoy the full benefits of this smart system. The unique technology of “NLZ” employs an all-new micromotor system and expands the possibilities of dental treatment. This original concept from the leading handpiece manufacturer provides cutting-edge features applicable to a wide-range of endodontic treatments with enhanced comfort and safety. A big change in treatment environment is brought with only a minor addition to the current equipment in your office.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cimg src=\"https:\/\/www.australia.nsk-dental.com\/admin\/wp-content\/uploads\/kf_micromotors.jpg\"\u003e\u003c\/li\u003e\n\u003cli\u003e \u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eElectric clinical micromotors\u003c\/strong\u003e\u003cbr\u003e- high speed rotation and torque\u003cbr\u003e- flexible speed variation\u003cbr\u003e- no maintenance\u003cbr\u003e- all clinical application use\u003cbr\u003e- ISO Type E easy to connect with all handpieces and contra-angles (NSK, KaVo®, Sirona®, W\u0026amp;H®, Bien-Air®)\u003cbr\u003e- Optic and non-optic\u003cbr\u003e- Internal water spray\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnology \u0026amp; Function\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cimg src=\"https:\/\/www.australia.nsk-dental.com\/admin\/wp-content\/uploads\/micromotor_nlz_01.png\" alt=\"POWERFUL\"\u003e\u003cstrong\u003ePOWERFUL\u003c\/strong\u003e\u003cp\u003eThe conventional magnet rotor has been replaced with an improved magnet rotor. More powerful rotation is achieved in the same amount of space by reducing weak magnetic areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003c\/li\u003e\n\u003cli\u003e\n\u003cimg src=\"https:\/\/www.australia.nsk-dental.com\/admin\/wp-content\/uploads\/micromotor_nlz_02.png\" alt=\"EFFICIENT\"\u003e\u003cstrong\u003eEFFICIENT\u003c\/strong\u003e\u003cp\u003eIn this unique technology, the water and air lines that used to bypass the motor have now been integrated with the motor. This new, more efﬁcient conﬁguration makes maximum use of the limited space and is lighter and more powerful than before.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003c\/li\u003e\n\u003cli\u003e\n\u003cimg src=\"https:\/\/www.australia.nsk-dental.com\/admin\/wp-content\/uploads\/micromotor_nlz_03.png\" alt=\"LESS HEAT\"\u003e\u003cstrong\u003eLESS HEAT\u003c\/strong\u003e\u003cp\u003eNLZ employs a simple non-layered coil instead of a standard layered coil. The coils are as compact as possible, shortening the pathway for heat generating current. As a result it generates less heat without reducing the output power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003c\/li\u003e\n\u003cli\u003e\n\u003cimg src=\"https:\/\/www.australia.nsk-dental.com\/admin\/wp-content\/uploads\/micromotor_nlz_04.png\" alt=\"SIMPLIFIED PIPE CONFIGURATION\"\u003e\u003cstrong\u003eSIMPLIFIED PIPE CONFIGURATION\u003c\/strong\u003e\u003cp\u003eConventional products include several pipes, which crank the water ﬂow supplied from the rear of the motor. The NLZ uses a simple straight pipe design instead of a crank, reducing the risk of water clogging in the rear section of the motor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003c\/li\u003e\n\u003cli\u003e\n\u003cimg src=\"https:\/\/www.australia.nsk-dental.com\/admin\/wp-content\/uploads\/micromotor_nlz_05.png\" alt=\"CONTAMINANTS ARE STOPPED BY A MICROFILTER\"\u003e\u003cstrong\u003eCONTAMINANTS ARE STOPPED BY A MICROFILTER\u003c\/strong\u003e\u003cp\u003eThere is a water ﬁlter with 0.3 mm diameter mesh ﬁtted within the tubing connector at the back of the main unit to catch debris and foreign particles in the water and prevent clogging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003c\/li\u003e\n\u003cli\u003e\n\u003cimg src=\"https:\/\/www.australia.nsk-dental.com\/admin\/wp-content\/uploads\/micromotor_nlz_06.png\" alt=\"ENDO TORQUE CALIBRATION FUNCTION （NLZ E only）\"\u003e\u003cstrong\u003eENDO TORQUE CALIBRATION FUNCTION （NLZ E only）\u003c\/strong\u003e\u003cp\u003ePerforming the “Contra-Check Function” also enables torque calibration. This function measures the no-load current values and corrects the torque accordingly, resulting in greatly enhanced safety in endodontic treatment.\u003cbr\u003e*This function cannot completely absorb the individual difference of the actual motor and contra-angles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"NSK","offers":[{"title":"Default Title","offer_id":47738093502613,"sku":"NSKY1500361","price":3431.51,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9917\/5829\/files\/NSKY1500361.jpg?v=1787029937","url":"https:\/\/shop.leadingdental.com.au\/products\/nsk-nlz-e-electric-micromotor-system-with-endodontic-function","provider":"Leading Dental","version":"1.0","type":"link"}